Our services

Backflow Testing and Repairs

Certified testing, reporting, troubleshooting, repairs and retesting for backflow assemblies. Serving Denver metro and Colorado’s Front Range.

Schedule backflow testing or a repair visit.

Send the property address, water provider, device information and due date. Include the last test report and any failure or leak details. AO will confirm testing, reporting, repair and retesting needs.

Schedule service

From testing to certification

  1. Due date or notice received
  2. Device tested on site
  3. Pass/fail results documented
  4. Report submitted or repair planned

Which backflow assembly needs testing?

Check your utility notice or last report for the device location, type and serial number. Each device may have its own test record.

Assembly types on a test report

Common labels include reduced pressure principle assembly (RP), double check valve assembly (DC) and pressure vacuum breaker (PVB). Include the type, make, model, size and serial number shown on your report. The water provider determines which assembly is appropriate for the connection.

Domestic water backflow testing

This is the assembly serving the building's domestic water supply. Send its last report and any access restrictions so AO can confirm the device and plan the test around the property's water use.

Irrigation backflow testing

An irrigation assembly serves the landscape watering system. Include the utility notice, device location and whether the irrigation water is currently on. Testing requirements depend on the water provider and property; a residential lawn system does not automatically follow the same program as a commercial property.

Fire-line backflow testing

A fire-line assembly protects the connection supplying a fire sprinkler system. Its backflow test and the sprinkler system inspection are distinct scopes. Tell AO about both due dates so access, any required notifications and the testing sequence can be coordinated.

Submit the report to the right water provider

Use the water provider on your bill or notice, which may differ from the city in your address. AO confirms where reports must go and records each device’s result.

Keep the test report and the submission confirmation with your property records. If an assembly fails, repair and retesting are the next steps toward a passing certification.

What affects a backflow testing quote?

Your quote depends on the number and type of devices, access, reporting and any repair or retest work. Send the address, water provider, due date and last report so AO can confirm the work and price.

Find the problem, repair and retest

  1. Identify failed check, relief valve, seal or shutoff issue
  2. Repair serviceable components or recommend replacement when needed
  3. Retest and document the assembly after work is complete

Repair work may include

  • Valve, seal and component replacement
  • Leak repair and troubleshooting
  • Device replacement planning when repair is not cost-effective
  • Post-repair testing and recertification

Confirm the problem before repair

A failed test identifies a performance problem. A leak alone does not show which part failed. AO reviews the report, device condition and available parts before recommending repair or replacement.

Certification requires a passing retest and the required report after repairs. Keep the repair findings and retest record together for future property managers and testers.

Information that helps prepare the visit

  • Failed report, utility notice and due date
  • Assembly make, model, size and serial number, if known
  • Whether the device serves domestic water, irrigation or a fire line
  • Location, access contact and any restrictions on interrupting service

For an active leak or urgent service issue, call AO at (720) 366-2273 so the situation can be discussed directly.

At a glance

How does AO handle backflow testing and repairs?

AO tests domestic, irrigation and fire-line backflow assemblies, documents results and submits reports where required. If a device fails, AO reviews repair or replacement options and arranges retesting to complete certification.

Common questions

What happens if a backflow device fails?

The device must be repaired or replaced and retested before certification can be completed.

Do water districts have different rules?

Yes. Due dates and reporting processes vary by water provider. AO can review your notice or account details to confirm the requirements.

What should I send after a failed test?

Send the failed report, a photo of the device or its tag, leak details and access notes.

Is replacement sometimes better than repair?

Yes. Replacement may be the better option if a device is badly worn, damaged or too costly to repair. AO can recommend the next step and arrange retesting.